F01P Series Flux Gate, Closed Loop Sensor 1-Channel Bidirectional -40°C~105°C 300kHz Accuracy-±1.7% Linearity-±1%

Delivery:

DHL
DHL
DHL
DHL

Payment:

DHL
DHL
DHL
DHL
DHL
DHL
DHL

In Stock :Available

Price not displayed? Please send an RFQ, and we will respond immediately.

F01P050S05 information

Tamura F01P050S05 technical specifications, attributes, parameters and parts with similar specifications to Tamura F01P050S05.

  • Type
  • Parameter
  • Factory Lead Time
  • 22 Weeks
  • Mount
  • PCB
  • Mounting Type
  • Through Hole
  • Package / Case
  • Module
  • Weight
  • 12.000013g
  • Operating Temperature
  • -40°C~105°C
  • Packaging
  • Bulk
  • Series
  • F01P
  • Published
  • 2001
  • Pbfree Code
  • yes
  • Part Status
  • Active
  • Moisture Sensitivity Level (MSL)
  • 1 (Unlimited)
  • Number of Terminations
  • 9
  • Terminal Position
  • UNSPECIFIED
  • Terminal Form
  • PIN/PEG
  • Peak Reflow Temperature (Cel)
  • NOT SPECIFIED
  • Number of Functions
  • 1
  • Supply Voltage
  • 5V
  • Current Rating
  • 50A
  • Frequency
  • 300kHz
  • Time@Peak Reflow Temperature-Max (s)
  • NOT SPECIFIED
  • Output
  • Ratiometric, Voltage
  • JESD-30 Code
  • R-XXSS-P9
  • Current - Supply (Max)
  • 55mA
  • Operating Supply Voltage
  • 5V
  • Number of Channels
  • 1
  • Analog IC - Other Type
  • ANALOG CIRCUIT
  • Polarization
  • Bidirectional
  • Max Supply Current
  • 55mA
  • Accuracy
  • ±1.7%
  • Response Time
  • 0.3μs
  • Sensor Type
  • Flux Gate, Closed Loop
  • Linearity
  • ±1%
  • For Measuring
  • AC
  • Sensitivity (mV/A)
  • 12.5 mV/A
  • Height
  • 18.7mm
  • Length
  • 23.2mm
  • Width
  • 12.7mm
  • RoHS Status
  • RoHS Compliant

Download datasheets and manufacturer documentation for Tamura F01P050S05.

F01P050S05 Overview


For safety reasons, the current sensors are packaged in Module packages. The current sensors are packaged in the Bulk in order to prevent damage to the devices. It is recommended that these current sensors supply a maximum current of 55mA. Current sensors should not supply a current greater than 55mA. There is a termination of 9 on the current sensors. Current sensors have been designed for 50A current. During operation, the current sensors may supply a voltage of 5V. During operation, these current sensors are capable of supplying a voltage of 5V. Current sensors should produce a voltage of 2.5V.

F01P050S05 Features


Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~105°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Flux Gate, Closed Loop
Frequency: 300kHz
Module Package


F01P050S05 Applications


There are a lot of Tamura
F01P050S05 Current Sensors applications.


  • Inverter and H-bridge current measurements
  • Power factor correction
  • Overcurrent protection
  • DC and AC power monitoring
  • Closed-L oop DC- and AC-Current Sensor Modules
  • Leakage Current Sensors
  • Industrial Monitoring and Control Systems
  • Overcurrent Detection
  • Frequency, Voltage, and Solar Inverters
  • Electrical drives

User Guide

PURCHASE

Please verify all part numbers, quantities, and packaging preferences before placing your order. If substitutions are acceptable, please indicate this clearly. For time-sensitive projects, confirm estimated delivery dates and stock availability in advance. Once submitted, changes or cancellations may not be possible, especially for items marked as non-cancellable/non-returnable (NCNR). For international shipments, please ensure all import documentation is complete and accurate to avoid delays.

MEANS OF PAYMENT

For your convenience, we accept multiple payment methods in USD, including PayPal, Credit Card, and Wire Transfer. Net terms may be available for qualified customers upon approval.

RFQ (REQUEST FOR QUOTATIONS)

Please ensure the part numbers and quantities are accurate and complete when submitting your RFQ.
Provide target prices and acceptable alternatives, if any, to speed up the quotation process.

IMPORTANT NOTICE

Quotations are subject to stock availability and may vary with market conditions. Prices and lead times are not guaranteed until a purchase order is confirmed. Ensure your contact details are correct to avoid delays in response.

Step1:Prepare product

Step1:Prepare product

Step2:Desiccant Protection

Step2:Desiccant Protection

Step3:Vacuum Packaging

Step3:Vacuum Packaging

Step4:Individual Package

Step4:Individual Package

Step5:Anti-collision Filling

Step5:Anti-collision Filling

Step6:Packaging Box

Step6:Packaging Box

SHIPPING COST

1. Shipping starts at $40, but some countries will exceed $40. For example (South Africa, Brazil, India, Pakistan, Israel, etc.).
2. Some specific products need to reach the minimum order quantity.
3. It may cost additional remote fees for delivery if you are in a remote area.

SHIPPING METHOD

Currently, our products are shipped through DHL, FedEx, SF, and UPS.

DELIVERY TIME

1. Once the goods are shipped, estimated delivery time depends on the shipping methods you chose: FedEx International, 5-7 business days.
2. For in-stock parts, orders normally could be shipped out within 1-2days.